The use or possession of the Radio Apparatus listed in Column B below, in accordance with all specifications listed in Columns A, C, D, and E of the Table below, shall not require a radio frequency spectrum licence. Compliance with the EMC and Safety Standards for the relevant Application Type is mandatory as prescribed in the Official List of ICASA Regulated Standards for Technical Equipment and Electronic Communications Facilities.

 

Table of radio frequency spectrum licence Exemptions

 

Column A

 

Frequency Bands

K=kHz

M=MHz

G=GHz

Column B

 

Application Type

Column C

 

Maximum Radiated

Power, Field Strength or Sensitivity Limits

Column D

 

Relevant Performance Standards

Column E

 

Reference

9 - 315K

Ultra Low Power Active Medical Implant

(ULP-AMI)

30 dBμA/m at 10 m

EN 302 195

CEPT/ERC/REC 70-03

9-135K

Inductive Applications

42 dBμA/m @ 10 m

(Additional restrictions apply to limits above 42 dBμA/m)

SANS 300 330

 

135-140K

Inductive Applications

42 dBμA/m @ 10 m

SANS 300 330

CEPT/ERC/REC 70-03

140-148.5K

Inductive Applications

37.7 dBμA/m @ 10 m

SANS 300 330

CEPT/ERC/REC 70-03

148.5-5000K

Inductive Applications

-15 dBμA/m @ 10 m

(Additional restrictions apply to limits above -15 dBμA/m)

SANS 300 330

CEPT/ERC/REC 70-03

315-600K

Ultra Low Power Animal Implantable (ULP-AID)

-5 dBμA /m @ 10 m

EN 302 536

 

400-600K

RFID Applications only

-8 dBμA/m @ 10 m

(Additional restrictions apply to limits above -8 dBμA/m)

SANS 300 330

CEPT/ERC/REC 70-03

456.9-457.1K

Emergency detection of buried victims and valuable items

7 dBμA/m at 10 m

EN 300 718

CEPT/ERC/REC 70-03

3.155-3.4M

Inductive Applications including Low Power Wireless Hearing Aid

13.5 dBμA/m @ 10 m

SANS 300 330

CEPT/ERC/REC 70-03

5-30M

Inductive Applications

-20 dBμA/m at 10 m

(Additional restrictions apply to limits above -20 dBμA/m)

SANS 300 330

CEPT/ERC/REC 70-03

6.765-6.795M

Inductive Applications

42 dBμA/m @ 10 m

SANS 300 330

CEPT/ERC/REC 70-03

7.4-8.8M

Inductive Applications

9 dBμA/m @ 10 m

SANS 300 330

CEPT/ERC/REC 70-03

10.2-11M

Inductive Applications including Low Power Wireless Hearing Aid

9 dBμA/m @ 10 m

SANS 300 330

CEPT/ERC/REC 70-03

13.553-13.567M

Inductive Applications

42 dBμA/m @ 10 m

SANS 300 330

CEPT/ERC/REC 70-03

13.553-13.567M

RFID (incl. NFC) and

EAS applications only

60 dBμA/m @ 10 m

SANS 300 330

CEPT/ERC/REC 70-03

13.553-13.567M

Non-specific SRD

10 mW e.r.p.

SANS 300 330

CEPT/ERC/REC 70-03

26.957-27.283M

Inductive Applications

42 dBμA/m @ 10 m

SANS 300 330

 

26.957-27.283M

Non-specific SRD

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

26.99-27.00M

Model Control Devices

100 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

27.04-27.05M

Model Control Devices

100 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

27.09-27.10M

Model Control Devices

100 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

27.14-27.15M

Model Control Devices

100 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

27.19-27.20M

Model Control Devices

100 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

29.7-47.0M

Wireless Microphones

10 mW e.r.p.

(Additional restrictions apply to limits above 10 mW)

SANS 300 422

CEPT/ERC/REC 70-03

30-37.5M

Ultra Low Power

medical membrane

implants (ULP-AMI-M)

1 mW e.r.p.

EN 302 510

CEPT/ERC/REC 70-03

34.995-35.225M

Aircraft Model Control

100 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

40.66-40.7M

Model Control Devices

100 mW e.r.p.

SANS 300 220

 

40.66-40.7M

Non-specific SRD

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

46.61-46.97M

49.67-49.97M

CT0 Cordless phones

10 mW e.r.p.

SANS 300 175

TE-013

Government Gazette 22443 of 4th July 2001

53-54M

Wireless Microphones

10 mW e.r.p.

SANS 300 422

 

54.4500M;

54.4625M;

54.4750M;

54.4875M;

54.500M;

54.5125M;

54.5250M;

54.5375M;

54.5500M

Model Control Devices

500 mW e.r.p.

SANS 300 220

 

138.2-138.45M

Non-specific SRD

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

141-142M

Remote Control Industrial Apparatus

100 mW e.r.p.

SANS 300 220

 

148-152M

Wildlife Telemetry Tracking

25 mW e.r.p.

SANS 300 220

 

169.4-169.475M

Meter Reading

500 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

169.4-169.475M

Assistive Listening Device (ALD)

500 mW e.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

169.4-169.475M

Non-Specific SRD

500 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

169.4-

169.4875M

Non-Specific SRD

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

169.4-174M

Assistive Listening Device (ALD)

10 mW e.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

169.4875-

169.5875M

Assistive Listening Device (ALD)

500 mW e.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

169.4875-

169.5875M

Non-Specific SRD

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

169.5875-

169.8125M

Non-Specific SRD

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

173.2125-

173.2375M

Non-specific SRD – telecommand only

10 mW e.r.p.

SANS 300 220

 

173.2375-

173.2875M

Non-Specific SRD

10 mW e.r.p.

SANS 300 220

 

173.965-216M

Assistive Listening Device (ALD)

10 mW e.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

174-216M

Wireless Microphones

50 mW e.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

401-402M

Ultra Low Medical Data Services (UL-MEDS)

25 μW e.r.p.

EN 302 537

CEPT/ERC/REC 70-03

402-405M

Ultra Low Power Active Medical Implant (ULP-AMI)

25 μW e.r.p.

EN 301 839

CEPT/ERC/REC 70-03

405-406M

Ultra Low Medical Data Services (UL-MEDS)

25 μW e.r.p.

EN 302 537

CEPT/ERC/REC 70-03

402-406M

Wireless Microphones

10 mW e.r.p.

SANS 300 422

 

402-406M

Doppler shift movement detectors, garage door openers and motor car alarm systems

10 mW e.r.p.

SANS 300 220

 

430-440M

Ultra-Low Power Wireless Medical Capsule Endoscopy (ULP-WMCE)

-40 dBm/10MHz

EN 303 520

CEPT/ERC/REC 70-03

433.05-434.79M

Non-specific SRD

1 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

433.05-434.79M

Non-specific SRD

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

446-446.2M

Public Mobile Radio (PMR) 446 Applications

500 mW e.r.p.

EN 303 405

CEPT/ERC/REC 70-03

463.975M;

464.125M;

464.175M;

464.325M;

464.375M;

Low Power Radio

500 mW e.r.p.

SANS 300 296

 

464.5375M

Security systems

1 W e.r.p.

SANS 300 296

 

464.5-

464.5875M

Non-specific SRD

100 mW e.r.p.

SANS 300 220

 

470-786M

Wireless Microphones

50 mW e.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

786-789M

Wireless Microphones

12 mW e.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

823-826M

Wireless Microphones

20 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

823-826M

Body Worn Equipment

100 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

826-832M

Wireless Microphones

100 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

862-863M

Non-Specific SRD

25 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

863-865M

Wireless Microphones

10 mW e.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

863-865M

Wireless audio and multimedia streaming devices

10 mW e.r.p.

SANS 301 357

CEPT/ERC/REC 70-03

863-870M

Non-Specific SRD

25 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

864.1-868.1M

CT2 Cordless phones

10 mW e.i.r.p.

SANS 301 797

TE - 012

 

865-868M

RFID Applications

2 W e.r.p.

SANS 302 208

CEPT/ERC/REC 70-03

868-868.6M

Non-Specific SRD

25 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

868.6-868.7M

Alarms

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

868.7-869.2M

Non-Specific SRD

25 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

869.2-869.25M

Social Alarm

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

869.25-869.3M

Alarms

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

869.3-869.4M

Alarms

10 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

869.4-869.65M

Non-Specific SRD

500 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

869.65-869.7M

Alarms

25 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

869.7-870M

Non-Specific SRD

5 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

869.7-870M

Non-specific SRD

25 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

915-919.4M

Non-specific SRD

25 mW e.r.p.

SANS 300 220

CEPT/ERC/REC 70-03

915.1-915.2M

Real Time Location System (RTLS)

25 mW e.r.p.

SANS 300 086

 

915.3-920.9M

Tag Transmit

-10 dBm e.r.p.

SANS 302 208

ECC Report 200

916.1-916.5M

Interrogator Transmit

4 W e.r.p.

SANS 302 208

ECC Report 200

917.3-917.7M

Interrogator Transmit

4 W e.r.p.

SANS 302 208

ECC Report 200

918.5-918.9M

Interrogator Transmit

4 W e.r.p.

SANS 302 208

ECC Report 200

919.7-920.1M

Interrogator Transmit

4 W e.r.p.

SANS 302 208

ECC Report 200

915.4-919M

Modulating RFID systems (FHSS)

4 W e.r.p.

FCC CFR 47

Part 15.247

 

1350-1400M

Wireless Microphones

20 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1350-1400M

Body Worn Equipment

50 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1492-1518M

Wireless Microphones

50 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1518-1525M

Wireless Microphones

50 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1656.5-1660.5M

Assistive Listening

Systems (ALS)

2 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1785-1795M

Wireless Microphones

20 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1785-1795M

Body Worn Equipment

50 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1795-1800M

Wireless Microphones

20 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1795-1800M

Body Worn Equipment

50 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1795-1800M

Wireless audio and multimedia streaming devices

20 mW e.i.r.p.

SANS 301 357

CEPT/ERC/REC 70-03

1800-1804.8M

Wireless Microphones

20 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1800-1804.8M

Body Worn Equipment

50 mW e.i.r.p.

SANS 300 422

CEPT/ERC/REC 70-03

1880-1900M

DECT Systems

250 mW e.i.r.p.

SANS 301 406

TE 001

CEPT/ERC/REC 70-03

2200-8500M

Radiodetermination Applications for Material Sensing

-30 dBm @ 50MHz

(Additional restrictions apply to limits above -30 dBm)

EN 302 065

ECC/DEC/(07)01

2400-2483.5M

Non-specific SRD

10 mW e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

2400-2483.5M

Wideband Data Transmission Systems (WBDTS)

100 mW e.i.r.p.

SANS 300 328

CEPT/ERC/REC 70-03

2400-2483.5M

Radiodetermination Applications

25 mW e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

2400-2483.5M

Low power Video Surveillance

100 mW e.i.r.p.

SANS 300 440

 

2446-2454M

RFID Applications

500 mW e.i.r.p.

(Additional restrictions apply to limits above 500 mW)

SANS 300 440

CEPT/ERC/REC 70-03

2483.5-2500M

Low Power Active

Medical Implants (LP-AMI) and peripherals

10 dBm e.i.r.p.

EN 301 559

CEPT/ERC/REC 70-03

2483.5-2500M

Medical Body Area Network System (MBANS) Indoor Only

1 mW e.i.r.p.

SANS 303 203

CEPT/ERC/REC 70-03

2483.5-2500M

Medical Body Area Network System (MBANS) Indoor Only

10 dBm e.i.r.p.

SANS 303 203

CEPT/ERC/REC 70-03

3100-3400M

Radiodetermination Application

-36 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

3400-3800M

Radiodetermination Application

-40 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

3400-4200M

Radiodetermination Application

For Location tracking application for emergency and disaster situations (LAES)

20 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

3400-4800M

Radiodetermination Application

For Location Tracking Systems TYPE 2 (LT2)

0 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

3800-4200M

Radiodetermination Application

-30 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

4200-4800M

Radiodetermination Application

-30 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

4200-4800M

Radiodetermination Application

For Location tracking application for emergency and disaster situations (LAES)

0 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

4500-7000M

Radiodetermination Application

24 dBm e.i.r.p. @ 50MHz

EN 302 372

CEPT/ERC/REC 70-03

5150-5250M

Wireless Access Systems / Radio Local Access Network (WAS/RLAN)

23 dBm e.i.r.p.

SANS 301 893

CEPT/ERC/REC 70-03

ITU Res 229 (WRC-19)

5250-5350M

Wireless Access Systems / Radio Local Access Network (WAS/RLAN)

23 dBm e.i.r.p.

SANS 301 893

CEPT/ERC/REC 70-03

ITU-R M.1652

ITU Res 229 (WRC-19)

5470-5725M

Wireless Access Systems / Radio Local Access Network (WAS/RLAN)

30 dBm e.i.r.p.

SANS 301 893

CEPT/ERC/REC 70-03

ITU-R M.1652

ITU Res 229 (WRC-19)

5725-5875M

Non-Specific SRD

25 mW e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

5725-5875M

Wireless Industrial Applications (WIA)

400 mW e.i.r.p.

EN 303 258

CEPT/ERC/REC 70-03

5725-5875M

Broadband Fixed Wireless Access systems (BFWA)

36 dBm e.i.r.p.

SANS 302 502

ECC/REC/(06)04

5725-5875M

Broadband Fixed Wireless Access systems (BFWA)

30 dBm e.i.r.p.

FCC 47 CFR

Part 15.247

 

5795-5805M

Transport and Traffic Telematics (TTT) Applications

2 W e.i.r.p.

SANS 300 674

CEPT/ERC/REC 70-03

5805-5815M

Transport and Traffic Telematics (TTT) Applications

2 W e.i.r.p.

SANS 300 674

CEPT/ERC/REC 70-03

5855-5875M

Intelligent Transportation Systems (ITS)

33 dBm e.i.r.p.

EN 302 571

ECC/REC (08)01

5875-5905M

Intelligent Transportation Systems (ITS)

33 dBm e.i.r.p.

EN 302 571

CEPT/ERC/REC 70-03

5905-5925M

Intelligent Transportation Systems (ITS)

33 dBm e.i.r.p.

EN 302 571

ECC/REC (08)01

6000-8500M

Radiodetermination Applications

0 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

6000-6650M

Radiodetermination Applications On-board Aircraft

0 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

6650-6675.2M

Radiodetermination Applications On-board Aircraft

-12 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

6675.2-8500M

Radiodetermination Applications On-board Aircraft

0 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

6000-8500M

Radiodetermination Applications

7 dBm e.i.r.p. @ 50MHz

EN 302 729

CEPT/ERC/REC 70-03

8500-9000M

Radiodetermination Applications

-25 dBm e.i.r.p. @ 50MHz

EN 302 065

CEPT/ERC/REC 70-03

8500M-10.6G

Radiodetermination Applications

30 dBm e.i.r.p. @ 50MHz

EN 302 372

CEPT/ERC/REC 70-03

9200-9500M

Radiodetermination Applications

25 mW e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

9500-9975M

Radiodetermination Applications

25 mW e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

10.025-10.145G

Low power Video Surveillance

1 W e.i.r.p.

I-ETS 300 440

 

10.5-10.6G

Radiodetermination Applications

500 mW e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

13.4-14G

Radiodetermination Applications

25 mW e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

17.1-17.3G

Radiodetermination Applications

26 dBm e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

17.1-17.3G

HiperLAN

100 mW e.i.r.p.

 

 

24-24.25G

Non-Specific SRD

100 mW e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

24.05-24.075G

Transport and Traffic Telematics (TTT) Applications

For Automotive Radars

100 mW e.i.r.p.

EN 302 858

CEPT/ERC/REC 70-03

24.05-24.25G

Radiodetermination Applications

100 mW e.i.r.p.

SANS 300 440

CEPT/ERC/REC 70-03

24.05-27G

Radiodetermination Applications

43 dBm e.i.r.p. @ 50MHz

EN 302 372

CEPT/ERC/REC 70-03

24.05-26.5G

Radiodetermination Applications

26 dBm e.i.r.p. @ 50MHz

EN 302 729

CEPT/ERC/REC 70-03

24.075-24.15G

Transport and Traffic

Telematics (TTT) Applications

For Automotive Radars

0.1 mW e.i.r.p.

EN 302 858

CEPT/ERC/REC 70-03

24.075-24.15G

Transport and Traffic

Telematics (TTT) Applications

For Automotive Radars (road vehicles only)

100 mW e.i.r.p.

EN 302 858

CEPT/ERC/REC 70-03

24.15-24.25G

Transport and Traffic

Telematics (TTT) Applications

For Automotive Radars (road vehicles only)

100 mW e.i.r.p.

EN 302 858

CEPT/ERC/REC 70-03

57-64G

Radiodetermination Applications

43 dBm e.i.r.p. @ 50MHz

EN 302 372

CEPT/ERC/REC 70-03

57-64G

Radiodetermination Applications

35 dBm e.i.r.p. @ 50MHz

EN 302 729

CEPT/ERC/REC 70-03

57-64G

Non-Specific SRD

100 mW e.i.r.p.

EN 305 550

CEPT/ERC/REC 70-03

57-64G

Point-to-point (P-P) Digital Fixed Radio Systems (DFRS)

55 dBm e.i.r.p.

SANS 302 217

ECC/REC (09)01

64-66G

Point-to-point (P-P) Digital Fixed Radio Systems (DFRS)

55 dBm e.i.r.p.

SANS 302 217

ECC/REC (05)02

57-71G

Multi-Gigabit Wireless Systems (MGWS)

40 dBm e.i.r.p.

EN 302 567

CEPT/ERC/REC 70-03

ECC Report 114

ECC Report 288

ITU-R Rec. M.2003

61-61.5G

Non-Specific SRD

100 mW e.i.r.p.

EN 305 550

CEPT/ERC/REC 70-03

63.72-65.88G

Intelligent Transportation Systems (ITS)

40 dBm e.i.r.p.

EN 302 686

CEPT/ERC/REC 70-03

75-85G

Radiodetermination Applications

43 dBm e.i.r.p. @ 50MHz

EN 302 372

CEPT/ERC/REC 70-03

75-85G

Radiodetermination Applications

34 dBm e.i.r.p. @ 50MHz

EN 302 729

CEPT/ERC/REC 70-03

76-77G

Transport and Traffic Telematics (TTT) Applications

55 dBm peak e.i.r.p.

EN 301 091

CEPT/ERC/REC 70-03

76-77G

Transport and Traffic Telematics (TTT) Applications

For Obstacle Detection Radars for rotorcraft use

30 dBm peak e.i.r.p.

EN 303 360

CEPT/ERC/REC 70-03

77-81G

Transport and Traffic Telematics (TTT) Applications

For Automotive Short Range Radars (SRR)

55 dBm e.i.r.p.

EN 302 264

CEPT/ERC/REC 70-03

 

Use and possession of all radio apparatus exempt in terms of the above table must comply with the following:

(a) All radio apparatus must be type-approved by the Authority in accordance with section 35 of the Act;
(b) The frequencies, transmitting power and external high-gain antenna of the radio apparatus must not be altered without a new type-approval certificate being issued by the Authority;
(c) The Radio Apparatus must be operated within, and not exceed, the technical parameters set out in each of the applicable columns C of the Table with respect to the frequency band; maximum radiated power or field strength or Sensitivity limits as prescribed in the relevant performance standard in Column D.
(d) The antenna of the Radio Apparatus must not be higher or above average ground level than the lowest point of the place where the Radio Apparatus operates effectively.
(e) The Radio Apparatus must not cause interference with any licensed radio frequency spectrum.
(f) The user of the Radio Apparatus in the licence-exempt frequency spectrum operates on non-interference and zero protection basis from interference.

 

[Annexure B substituted by Radio Frequency Spectrum Amendment Regulations, 2021, by section 3 of Notice No. 737, GG45690, dated 24 December 2021]

 

Reasons Document for the Annexure B of the Radio Frequency Spectrum Regulations 2015 - December 2021