The use or possession of the Radio Apparatus listed in Column B below, in accordance with all specifications listed in Columns A, C, D, and E of the Table below, shall not require a radio frequency spectrum licence. Compliance with the EMC and Safety Standards for the relevant Application Type is mandatory as prescribed in the Official List of ICASA Regulated Standards for Technical Equipment and Electronic Communications Facilities.
Table of radio frequency spectrum licence Exemptions
Column A
Frequency Bands K=kHz M=MHz G=GHz |
Column B
Application Type |
Column C
Maximum Radiated Power, Field Strength or Sensitivity Limits |
Column D
Relevant Performance Standards |
Column E
Reference |
9 - 315K |
Ultra Low Power Active Medical Implant (ULP-AMI) |
30 dBμA/m at 10 m |
EN 302 195 |
CEPT/ERC/REC 70-03 |
9-135K |
Inductive Applications |
42 dBμA/m @ 10 m (Additional restrictions apply to limits above 42 dBμA/m) |
SANS 300 330 |
|
135-140K |
Inductive Applications |
42 dBμA/m @ 10 m |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
140-148.5K |
Inductive Applications |
37.7 dBμA/m @ 10 m |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
148.5-5000K |
Inductive Applications |
-15 dBμA/m @ 10 m (Additional restrictions apply to limits above -15 dBμA/m) |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
315-600K |
Ultra Low Power Animal Implantable (ULP-AID) |
-5 dBμA /m @ 10 m |
EN 302 536 |
|
400-600K |
RFID Applications only |
-8 dBμA/m @ 10 m (Additional restrictions apply to limits above -8 dBμA/m) |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
456.9-457.1K |
Emergency detection of buried victims and valuable items |
7 dBμA/m at 10 m |
EN 300 718 |
CEPT/ERC/REC 70-03 |
3.155-3.4M |
Inductive Applications including Low Power Wireless Hearing Aid |
13.5 dBμA/m @ 10 m |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
5-30M |
Inductive Applications |
-20 dBμA/m at 10 m (Additional restrictions apply to limits above -20 dBμA/m) |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
6.765-6.795M |
Inductive Applications |
42 dBμA/m @ 10 m |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
7.4-8.8M |
Inductive Applications |
9 dBμA/m @ 10 m |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
10.2-11M |
Inductive Applications including Low Power Wireless Hearing Aid |
9 dBμA/m @ 10 m |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
13.553-13.567M |
Inductive Applications |
42 dBμA/m @ 10 m |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
13.553-13.567M |
RFID (incl. NFC) and EAS applications only |
60 dBμA/m @ 10 m |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
13.553-13.567M |
Non-specific SRD |
10 mW e.r.p. |
SANS 300 330 |
CEPT/ERC/REC 70-03 |
26.957-27.283M |
Inductive Applications |
42 dBμA/m @ 10 m |
SANS 300 330 |
|
26.957-27.283M |
Non-specific SRD |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
26.99-27.00M |
Model Control Devices |
100 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
27.04-27.05M |
Model Control Devices |
100 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
27.09-27.10M |
Model Control Devices |
100 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
27.14-27.15M |
Model Control Devices |
100 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
27.19-27.20M |
Model Control Devices |
100 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
29.7-47.0M |
Wireless Microphones |
10 mW e.r.p. (Additional restrictions apply to limits above 10 mW) |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
30-37.5M |
Ultra Low Power medical membrane implants (ULP-AMI-M) |
1 mW e.r.p. |
EN 302 510 |
CEPT/ERC/REC 70-03 |
34.995-35.225M |
Aircraft Model Control |
100 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
40.66-40.7M |
Model Control Devices |
100 mW e.r.p. |
SANS 300 220 |
|
40.66-40.7M |
Non-specific SRD |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
46.61-46.97M 49.67-49.97M |
CT0 Cordless phones |
10 mW e.r.p. |
SANS 300 175 TE-013 |
Government Gazette 22443 of 4th July 2001 |
53-54M |
Wireless Microphones |
10 mW e.r.p. |
SANS 300 422 |
|
54.4500M; 54.4625M; 54.4750M; 54.4875M; 54.500M; 54.5125M; 54.5250M; 54.5375M; 54.5500M |
Model Control Devices |
500 mW e.r.p. |
SANS 300 220 |
|
138.2-138.45M |
Non-specific SRD |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
141-142M |
Remote Control Industrial Apparatus |
100 mW e.r.p. |
SANS 300 220 |
|
148-152M |
Wildlife Telemetry Tracking |
25 mW e.r.p. |
SANS 300 220 |
|
169.4-169.475M |
Meter Reading |
500 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
169.4-169.475M |
Assistive Listening Device (ALD) |
500 mW e.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
169.4-169.475M |
Non-Specific SRD |
500 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
169.4- 169.4875M |
Non-Specific SRD |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
169.4-174M |
Assistive Listening Device (ALD) |
10 mW e.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
169.4875- 169.5875M |
Assistive Listening Device (ALD) |
500 mW e.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
169.4875- 169.5875M |
Non-Specific SRD |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
169.5875- 169.8125M |
Non-Specific SRD |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
173.2125- 173.2375M |
Non-specific SRD – telecommand only |
10 mW e.r.p. |
SANS 300 220 |
|
173.2375- 173.2875M |
Non-Specific SRD |
10 mW e.r.p. |
SANS 300 220 |
|
173.965-216M |
Assistive Listening Device (ALD) |
10 mW e.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
174-216M |
Wireless Microphones |
50 mW e.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
401-402M |
Ultra Low Medical Data Services (UL-MEDS) |
25 μW e.r.p. |
EN 302 537 |
CEPT/ERC/REC 70-03 |
402-405M |
Ultra Low Power Active Medical Implant (ULP-AMI) |
25 μW e.r.p. |
EN 301 839 |
CEPT/ERC/REC 70-03 |
405-406M |
Ultra Low Medical Data Services (UL-MEDS) |
25 μW e.r.p. |
EN 302 537 |
CEPT/ERC/REC 70-03 |
402-406M |
Wireless Microphones |
10 mW e.r.p. |
SANS 300 422 |
|
402-406M |
Doppler shift movement detectors, garage door openers and motor car alarm systems |
10 mW e.r.p. |
SANS 300 220 |
|
430-440M |
Ultra-Low Power Wireless Medical Capsule Endoscopy (ULP-WMCE) |
-40 dBm/10MHz |
EN 303 520 |
CEPT/ERC/REC 70-03 |
433.05-434.79M |
Non-specific SRD |
1 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
433.05-434.79M |
Non-specific SRD |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
446-446.2M |
Public Mobile Radio (PMR) 446 Applications |
500 mW e.r.p. |
EN 303 405 |
CEPT/ERC/REC 70-03 |
463.975M; 464.125M; 464.175M; 464.325M; 464.375M; |
Low Power Radio |
500 mW e.r.p. |
SANS 300 296 |
|
464.5375M |
Security systems |
1 W e.r.p. |
SANS 300 296 |
|
464.5- 464.5875M |
Non-specific SRD |
100 mW e.r.p. |
SANS 300 220 |
|
470-786M |
Wireless Microphones |
50 mW e.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
786-789M |
Wireless Microphones |
12 mW e.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
823-826M |
Wireless Microphones |
20 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
823-826M |
Body Worn Equipment |
100 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
826-832M |
Wireless Microphones |
100 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
862-863M |
Non-Specific SRD |
25 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
863-865M |
Wireless Microphones |
10 mW e.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
863-865M |
Wireless audio and multimedia streaming devices |
10 mW e.r.p. |
SANS 301 357 |
CEPT/ERC/REC 70-03 |
863-870M |
Non-Specific SRD |
25 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
864.1-868.1M |
CT2 Cordless phones |
10 mW e.i.r.p. |
SANS 301 797 TE - 012 |
|
865-868M |
RFID Applications |
2 W e.r.p. |
SANS 302 208 |
CEPT/ERC/REC 70-03 |
868-868.6M |
Non-Specific SRD |
25 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
868.6-868.7M |
Alarms |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
868.7-869.2M |
Non-Specific SRD |
25 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
869.2-869.25M |
Social Alarm |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
869.25-869.3M |
Alarms |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
869.3-869.4M |
Alarms |
10 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
869.4-869.65M |
Non-Specific SRD |
500 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
869.65-869.7M |
Alarms |
25 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
869.7-870M |
Non-Specific SRD |
5 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
869.7-870M |
Non-specific SRD |
25 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
915-919.4M |
Non-specific SRD |
25 mW e.r.p. |
SANS 300 220 |
CEPT/ERC/REC 70-03 |
915.1-915.2M |
Real Time Location System (RTLS) |
25 mW e.r.p. |
SANS 300 086 |
|
915.3-920.9M |
Tag Transmit |
-10 dBm e.r.p. |
SANS 302 208 |
ECC Report 200 |
916.1-916.5M |
Interrogator Transmit |
4 W e.r.p. |
SANS 302 208 |
ECC Report 200 |
917.3-917.7M |
Interrogator Transmit |
4 W e.r.p. |
SANS 302 208 |
ECC Report 200 |
918.5-918.9M |
Interrogator Transmit |
4 W e.r.p. |
SANS 302 208 |
ECC Report 200 |
919.7-920.1M |
Interrogator Transmit |
4 W e.r.p. |
SANS 302 208 |
ECC Report 200 |
915.4-919M |
Modulating RFID systems (FHSS) |
4 W e.r.p. |
FCC CFR 47 Part 15.247 |
|
1350-1400M |
Wireless Microphones |
20 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1350-1400M |
Body Worn Equipment |
50 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1492-1518M |
Wireless Microphones |
50 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1518-1525M |
Wireless Microphones |
50 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1656.5-1660.5M |
Assistive Listening Systems (ALS) |
2 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1785-1795M |
Wireless Microphones |
20 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1785-1795M |
Body Worn Equipment |
50 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1795-1800M |
Wireless Microphones |
20 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1795-1800M |
Body Worn Equipment |
50 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1795-1800M |
Wireless audio and multimedia streaming devices |
20 mW e.i.r.p. |
SANS 301 357 |
CEPT/ERC/REC 70-03 |
1800-1804.8M |
Wireless Microphones |
20 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1800-1804.8M |
Body Worn Equipment |
50 mW e.i.r.p. |
SANS 300 422 |
CEPT/ERC/REC 70-03 |
1880-1900M |
DECT Systems |
250 mW e.i.r.p. |
SANS 301 406 TE 001 |
CEPT/ERC/REC 70-03 |
2200-8500M |
Radiodetermination Applications for Material Sensing |
-30 dBm @ 50MHz (Additional restrictions apply to limits above -30 dBm) |
EN 302 065 |
ECC/DEC/(07)01 |
2400-2483.5M |
Non-specific SRD |
10 mW e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
2400-2483.5M |
Wideband Data Transmission Systems (WBDTS) |
100 mW e.i.r.p. |
SANS 300 328 |
CEPT/ERC/REC 70-03 |
2400-2483.5M |
Radiodetermination Applications |
25 mW e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
2400-2483.5M |
Low power Video Surveillance |
100 mW e.i.r.p. |
SANS 300 440 |
|
2446-2454M |
RFID Applications |
500 mW e.i.r.p. (Additional restrictions apply to limits above 500 mW) |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
2483.5-2500M |
Low Power Active Medical Implants (LP-AMI) and peripherals |
10 dBm e.i.r.p. |
EN 301 559 |
CEPT/ERC/REC 70-03 |
2483.5-2500M |
Medical Body Area Network System (MBANS) Indoor Only |
1 mW e.i.r.p. |
SANS 303 203 |
CEPT/ERC/REC 70-03 |
2483.5-2500M |
Medical Body Area Network System (MBANS) Indoor Only |
10 dBm e.i.r.p. |
SANS 303 203 |
CEPT/ERC/REC 70-03 |
3100-3400M |
Radiodetermination Application |
-36 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
3400-3800M |
Radiodetermination Application |
-40 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
3400-4200M |
Radiodetermination Application For Location tracking application for emergency and disaster situations (LAES) |
20 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
3400-4800M |
Radiodetermination Application For Location Tracking Systems TYPE 2 (LT2) |
0 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
3800-4200M |
Radiodetermination Application |
-30 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
4200-4800M |
Radiodetermination Application |
-30 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
4200-4800M |
Radiodetermination Application For Location tracking application for emergency and disaster situations (LAES) |
0 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
4500-7000M |
Radiodetermination Application |
24 dBm e.i.r.p. @ 50MHz |
EN 302 372 |
CEPT/ERC/REC 70-03 |
5150-5250M |
Wireless Access Systems / Radio Local Access Network (WAS/RLAN) |
23 dBm e.i.r.p. |
SANS 301 893 |
CEPT/ERC/REC 70-03 ITU Res 229 (WRC-19) |
5250-5350M |
Wireless Access Systems / Radio Local Access Network (WAS/RLAN) |
23 dBm e.i.r.p. |
SANS 301 893 |
CEPT/ERC/REC 70-03 ITU-R M.1652 ITU Res 229 (WRC-19) |
5470-5725M |
Wireless Access Systems / Radio Local Access Network (WAS/RLAN) |
30 dBm e.i.r.p. |
SANS 301 893 |
CEPT/ERC/REC 70-03 ITU-R M.1652 ITU Res 229 (WRC-19) |
5725-5875M |
Non-Specific SRD |
25 mW e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
5725-5875M |
Wireless Industrial Applications (WIA) |
400 mW e.i.r.p. |
EN 303 258 |
CEPT/ERC/REC 70-03 |
5725-5875M |
Broadband Fixed Wireless Access systems (BFWA) |
36 dBm e.i.r.p. |
SANS 302 502 |
ECC/REC/(06)04 |
5725-5875M |
Broadband Fixed Wireless Access systems (BFWA) |
30 dBm e.i.r.p. |
FCC 47 CFR Part 15.247 |
|
5795-5805M |
Transport and Traffic Telematics (TTT) Applications |
2 W e.i.r.p. |
SANS 300 674 |
CEPT/ERC/REC 70-03 |
5805-5815M |
Transport and Traffic Telematics (TTT) Applications |
2 W e.i.r.p. |
SANS 300 674 |
CEPT/ERC/REC 70-03 |
5855-5875M |
Intelligent Transportation Systems (ITS) |
33 dBm e.i.r.p. |
EN 302 571 |
ECC/REC (08)01 |
5875-5905M |
Intelligent Transportation Systems (ITS) |
33 dBm e.i.r.p. |
EN 302 571 |
CEPT/ERC/REC 70-03 |
5905-5925M |
Intelligent Transportation Systems (ITS) |
33 dBm e.i.r.p. |
EN 302 571 |
ECC/REC (08)01 |
6000-8500M |
Radiodetermination Applications |
0 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
6000-6650M |
Radiodetermination Applications On-board Aircraft |
0 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
6650-6675.2M |
Radiodetermination Applications On-board Aircraft |
-12 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
6675.2-8500M |
Radiodetermination Applications On-board Aircraft |
0 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
6000-8500M |
Radiodetermination Applications |
7 dBm e.i.r.p. @ 50MHz |
EN 302 729 |
CEPT/ERC/REC 70-03 |
8500-9000M |
Radiodetermination Applications |
-25 dBm e.i.r.p. @ 50MHz |
EN 302 065 |
CEPT/ERC/REC 70-03 |
8500M-10.6G |
Radiodetermination Applications |
30 dBm e.i.r.p. @ 50MHz |
EN 302 372 |
CEPT/ERC/REC 70-03 |
9200-9500M |
Radiodetermination Applications |
25 mW e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
9500-9975M |
Radiodetermination Applications |
25 mW e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
10.025-10.145G |
Low power Video Surveillance |
1 W e.i.r.p. |
I-ETS 300 440 |
|
10.5-10.6G |
Radiodetermination Applications |
500 mW e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
13.4-14G |
Radiodetermination Applications |
25 mW e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
17.1-17.3G |
Radiodetermination Applications |
26 dBm e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
17.1-17.3G |
HiperLAN |
100 mW e.i.r.p. |
|
|
24-24.25G |
Non-Specific SRD |
100 mW e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
24.05-24.075G |
Transport and Traffic Telematics (TTT) Applications For Automotive Radars |
100 mW e.i.r.p. |
EN 302 858 |
CEPT/ERC/REC 70-03 |
24.05-24.25G |
Radiodetermination Applications |
100 mW e.i.r.p. |
SANS 300 440 |
CEPT/ERC/REC 70-03 |
24.05-27G |
Radiodetermination Applications |
43 dBm e.i.r.p. @ 50MHz |
EN 302 372 |
CEPT/ERC/REC 70-03 |
24.05-26.5G |
Radiodetermination Applications |
26 dBm e.i.r.p. @ 50MHz |
EN 302 729 |
CEPT/ERC/REC 70-03 |
24.075-24.15G |
Transport and Traffic Telematics (TTT) Applications For Automotive Radars |
0.1 mW e.i.r.p. |
EN 302 858 |
CEPT/ERC/REC 70-03 |
24.075-24.15G |
Transport and Traffic Telematics (TTT) Applications For Automotive Radars (road vehicles only) |
100 mW e.i.r.p. |
EN 302 858 |
CEPT/ERC/REC 70-03 |
24.15-24.25G |
Transport and Traffic Telematics (TTT) Applications For Automotive Radars (road vehicles only) |
100 mW e.i.r.p. |
EN 302 858 |
CEPT/ERC/REC 70-03 |
57-64G |
Radiodetermination Applications |
43 dBm e.i.r.p. @ 50MHz |
EN 302 372 |
CEPT/ERC/REC 70-03 |
57-64G |
Radiodetermination Applications |
35 dBm e.i.r.p. @ 50MHz |
EN 302 729 |
CEPT/ERC/REC 70-03 |
57-64G |
Non-Specific SRD |
100 mW e.i.r.p. |
EN 305 550 |
CEPT/ERC/REC 70-03 |
57-64G |
Point-to-point (P-P) Digital Fixed Radio Systems (DFRS) |
55 dBm e.i.r.p. |
SANS 302 217 |
ECC/REC (09)01 |
64-66G |
Point-to-point (P-P) Digital Fixed Radio Systems (DFRS) |
55 dBm e.i.r.p. |
SANS 302 217 |
ECC/REC (05)02 |
57-71G |
Multi-Gigabit Wireless Systems (MGWS) |
40 dBm e.i.r.p. |
EN 302 567 |
CEPT/ERC/REC 70-03 ECC Report 114 ECC Report 288 ITU-R Rec. M.2003 |
61-61.5G |
Non-Specific SRD |
100 mW e.i.r.p. |
EN 305 550 |
CEPT/ERC/REC 70-03 |
63.72-65.88G |
Intelligent Transportation Systems (ITS) |
40 dBm e.i.r.p. |
EN 302 686 |
CEPT/ERC/REC 70-03 |
75-85G |
Radiodetermination Applications |
43 dBm e.i.r.p. @ 50MHz |
EN 302 372 |
CEPT/ERC/REC 70-03 |
75-85G |
Radiodetermination Applications |
34 dBm e.i.r.p. @ 50MHz |
EN 302 729 |
CEPT/ERC/REC 70-03 |
76-77G |
Transport and Traffic Telematics (TTT) Applications |
55 dBm peak e.i.r.p. |
EN 301 091 |
CEPT/ERC/REC 70-03 |
76-77G |
Transport and Traffic Telematics (TTT) Applications For Obstacle Detection Radars for rotorcraft use |
30 dBm peak e.i.r.p. |
EN 303 360 |
CEPT/ERC/REC 70-03 |
77-81G |
Transport and Traffic Telematics (TTT) Applications For Automotive Short Range Radars (SRR) |
55 dBm e.i.r.p. |
EN 302 264 |
CEPT/ERC/REC 70-03 |
Use and possession of all radio apparatus exempt in terms of the above table must comply with the following:
(a) | All radio apparatus must be type-approved by the Authority in accordance with section 35 of the Act; |
(b) | The frequencies, transmitting power and external high-gain antenna of the radio apparatus must not be altered without a new type-approval certificate being issued by the Authority; |
(c) | The Radio Apparatus must be operated within, and not exceed, the technical parameters set out in each of the applicable columns C of the Table with respect to the frequency band; maximum radiated power or field strength or Sensitivity limits as prescribed in the relevant performance standard in Column D. |
(d) | The antenna of the Radio Apparatus must not be higher or above average ground level than the lowest point of the place where the Radio Apparatus operates effectively. |
(e) | The Radio Apparatus must not cause interference with any licensed radio frequency spectrum. |
(f) | The user of the Radio Apparatus in the licence-exempt frequency spectrum operates on non-interference and zero protection basis from interference. |
[Annexure B substituted by Radio Frequency Spectrum Amendment Regulations, 2021, by section 3 of Notice No. 737, GG45690, dated 24 December 2021]