Statistics Act, 1999
R 385
Merchant Shipping Act, 1951 (Act No. 57 of 1951)SchedulesSecond ScheduleProtocol of 1978 Relating to the International Convention for the Safety of Life at Sea, 1974AnnexChapter II-2 : Construction—Fire Protection, Fire Detection and Fire ExtinctionPart B — Fire Safety Measures for Passenger Ships Carrying More than 36 PassengersRegulation 27 : Restriction of combustible materials |
(a) | Except in cargo spaces, mail rooms, baggage rooms, or refrigerated compartments of service spaces, all linings, grounds, ceilings and insulations shall be of noncombustible material. Partial bulkheads or decks used to subdivide a space for utility or artistic treatment shall also be of noncombustible material. |
(b) | Vapour barriers and adhesives used in conjunction with insulation, as well as insulation of pipe fittings, for cold service systems need not be noncombustible, but they shall be kept to the minimum quantity practicable and their exposed surfaces shall have qualities of resistance to the propagation of flame to the satisfaction of the Administration. |
(c) | Bulkheads, linings and ceilings in all accommodation and service spaces may have combustible veneer, provided that such veneer shall not exceed 2 millimetres (1/12 inch) within any such spaces except corridors, stairway enclosures and control stations where it shall not exceed 1,5 millimetres (1/17 inch). |
(d) | The total volume of combustible facings, mouldings, decorations and veneers in any accommodation and service space shall not exceed a volume equivalent to 2,5 millimetres (1/10 inch) veneer on the combined area of the walls and ceilings. In the case of ships fitted with an automatic sprinkler system complying with the provisions of Regulation 12 of this Chapter, the above volume may include some combustible material used for erection of “C” Class divisions. |
(e) | All exposed surfaces in corridors or stairway enclosures and surfaces in concealed or inaccessible spaces in accommodation and service spaces and control stations shall have low flame-spread characteristics. |
(f) | Furniture in the passages and stairway enclosures shall be kept to a minimum. |
(g) | Paints, varnishes and other finishes used on exposed interior surfaces shall not be of a nature to offer an undue fire hazard in the judgment of the Administration and shall not be capable of producing excessive quantities of smoke or other toxic properties. |
(h) | Primary deck coverings, if applied, within accommodation and service spaces and control stations, shall be of approved material which will not readily ignite, or give rise to toxic or explosive hazards at elevated temperatures. |
(i) | Wastepaper receptacles shall be constructed of noncombustible materials and with solid sides and bottoms. |