Acts Online
GT Shield

Mineral and Petroleum Resources Development Act, 2002 (Act No. 28 of 2002)

Regulations

Amendment Regulations to the Mineral and Petroleum Resources Development Regulations, 2020

Chapter 8 : Well Design and Construction

101. Centralisers

 

(1) Casing must be centralised in each segment of the wellbore to provide sufficient casing standoff and foster effective circulation of cement to isolate critical zones including aquifers, flow- zones, voids, lost circulation zones and hydrocarbon production zones.

 

(2) Surface casing must be centralised at the shoe, above and below a stage collar or diverting tool, and through fresh water zones.

 

(3) In non-deviated holes, a pipe centraliser must be placed every fourth joint from the cellar cement shoe to the ground surface or to the bottom of the cellar.

 

(4) Centralisers must be in accordance with the standards of—
(a) API "10 D, Specification for Bow-Spring Casing Centralizers and all rigid centralizers ";
(b) API "10 TR 4 Considerations Regarding Selection of Centralizers for Primary Cementing Operations "; and
(c) API RP "10D -2, Recommended Practice for Centralizer Placement and Stop Collar Testing ".

 

(5) The designated agency may require additional centralisation where necessary in order to ensure the adequacy of the integrity of the well design.

 

[Regulation 101 inserted by section 2 of Notice No. R. 466 dated 3 June 2015]