Acts Online
GT Shield

Standards Act, 2008 (Act No. 8 of 2008)

Notices

Standards Matters - 2009

Schedules

Schedule 2 : Amendment of Existing Standards

 

The standards mentioned have been amended in terms of section 16(3) of the Act. The number and date of a standard that has been superseded appear in brackets below the new number. In the case of an amendment issued in consolidated format, the edition number of the new (consolidated) edition appears in brackets below the number of the standard.

 

Standard No.

and year

Title, scope and purport

SANS 149:2009

(Ed. 2.4)

Absorbent cotton wool and cotton-and-viscose wool products. Consolidated edition incorporating amendment No. 4. Amended to update referenced standards.

SANS 212:2009/

CISPR 12:2009

(Ed. 1.2)

Vehicles, boats, and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers. Consolidated edition incorporating amendment No. 1. Amended to include traction batteries in the scope, and add floor treatment machines under the definitions for vehicle and device.

SANS 214-2:2009/

CISPR 14-2:2008

(Ed. 1.2)

Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard. Consolidated edition incorporating amendment No. 2. Amended to update referenced standards, add a definition for clock frequency, and change/replace text and tables relating to tests for surges and for voltage dips and interruptions.

SANS 216-1-2:2007/

CISPR 16-1-2:2006

(Ed. 1.2)

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances. Consolidated edition incorporating CISPR technical corrigendum No. 1. Corrected to move text in Figure E.4, delete text in Figure E.5 and correct and equation.

SANS 216-1-4:2008/

CISPR 16-1-4:2008

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Radiated disturbances. CISPR amendment No. 2. Amendment to add Specification of ferrite clamps type of  Common mode absorption devices (CMAD) which are used during radiated measurements in the frequency range 30 MHz to 1000 MHz for the purpose of reducing compliance uncertainty.

SANS 220:2009

(Ed. 3.2)

Dissolved acetylene cylinders. Consolidated edition incorporating amendment No. 2. Amended to change the designation of SABS standards to SANS standards, to update the definition of "acceptable", to delete reference to the standardization mark, and to update the referenced standards.

SANS 585:2009

(SABS 585:2009)

The production of frozen fish, marine molluscs, and products derived therefrom. Specifies requirements for the handling, preparation, processing, packaging, transportation, freezing, storage and quality of frozen fish, marine molluscs, and products derived therefrom which are intended for human consumption. It also specifies requirements for factories and employees involved in the production.

SANS 1700-12-3:2009/

ISO 4027:2003

Fasteners - Part 12: Set screws Section 3: Hexagon socket set screws with cone point. Specifies the characteristics of hexagon socket set screws with cone point and threads from M1,6 up to and including M24 and of product grade A.

SANS 1796:2009

(SABS 1796:2003)

Application of durable organic powder coatings for architectural aluminium. Specifies the characteristics of durable organic powder coating (finish) on aluminium alloy extrusions, sheet and welded structures to be used for external architectural applications. It includes powder coatings used for special finishes.

SANS 1803-1:2009

(Ed. 1.1)

Lugs and ferrules for insulated electric cables - Part 1: copper conductors. Consolidated edition incorporating amendment No. 1. Amended to change the designation of SABS standards of SABS standards to SANS standards, to update referenced standards, and to remove a reference to the SABS as the testing authority.

SANS 1808-13:2009

(Ed. 1.2)

Water supply and distribution system components - Part 13: Diaphragm valves. Consolidated edition incorporating amendment No. 1. Amended to change the designation of SABS standards to SANS standards, to update referenced standards, to update the definition of "acceptable", to update the requirements for fasteners, and to delete reference to the certification mark.

SANS 7816-4:2005/

ISO/IEC 7816-4:2005

(SABS ISO/IEC 7816-4:2005)

Identification cards - Integrated circuit cards - Part 4: Organization, security and commands for interchange. Specifies contents of command-response pairs exchanged at the interface; means of retrieval of data elements and data objects in the card; structures and contents of historical bytes to describe operating characteristics of the card; structures for applications and data in the card, as seen at the interface when processing commands; access methods to files  and data in the card; a security architecture defining access rights to files and data in the card; means and mechanisms for identifying and addressing applications in the card; methods for secure messaging; access methods to the algorithms  processed by the card. It does not describe these algorithms. It does not cover the internal implementation within the card or the outside world, and is independent from the physical interface technology. It applies to cards accessed by one or more of the following methods; contacts, close coupling, and radio frequency.

SANS 10114-2:2009

(Ed. 1.2)

Interior lighting - Part 2: Emergency lighting. Consolidated edition incorporating amendment No. 2. Amended to change the designation of SABS standards to SANS standards, and to move references to legislation to the foreword.

SANS 10249:2009

(Ed, 1.1)

Masonry walling. Consolidated edition incorporating amendment No. 1. Amended to change the designation of SABS standards to SANS standards, to update the introductory paragraph to the normative references clause, and to update referenced standards.

SANS 10373-6:2004/

IEC 10373-6:2001

Identification cards - Test methods - Part 6: Proximity cards. ISO/IEC amendment No. 1. Amended protocol test methods for proximity cards, added normative references, terms and definitions, a list of abbreviations and symbols and annex G, Additional PICC test methods. ISO/IEC amendment No. 5. Amended to include additional test conditions for Bit rates of fc/64, fc/32 and fc/16, to replace text in amendment 2:2003

SANS 12488-1:2077/

ISO 12488-1:2005

Cranes - Tolerances for wheels and travel and traversing tracts - Part 1: General  ISO corrigendum No. 1. Corrected to change and to add symbols, tolerances and variables in the clause on symbols (clause 4), the table on construction tolerances for crane wheels of tolerances classes 1 to 4 (table 4), the table on construction tolerances for rail joints (table 6), and the table on operational tolerances for travel and traverse tracks and traverse tracks and crane and crab wheels of tolerances classes 1 to 4 (table 7).

SANS 14692-2:2009/

ISO 14692-2:2002:

Petroleum and natural gas industries - Glass-reinforced plastics (GRP) piping - Part 2: Qualification and manufacture. ISO amendment No. 1. Corrected to include a note and to modify information on quantifying performance in annex D.

SANS 14692-3:2009/

ISO 14692-3:2002

Petroleum and natural gas industries - Glass-reinforced plastics (GRP) piping - Part 3: System design. ISO amendment No. 1. Corrected to modify a requirement in table 2 and to replace two equations.

SANS 14692-4:2009/

ISO 14692-4:2002

Petroleum and natural gas industries - Glass-reinforced plastics (GRP) piping - Part 4: Fabrication, installation and operation. ISO amendment No. 1. Corrected to modify the table on defect types, acceptance criteria and recommended corrective action for GRP material and adhesive bonds and to change a reference in the bibliography.

SANS 15189:2009/

ISO 15189:2007

Medical laboratories - Particular requirements for quality and competence. Specifies requirements for quality and competence particular to medical laboratories. For use by medical laboratories in developing their quality management systems and assessing their own competence, and for use by accreditation bodies in confirming or recognising the competence of medical laboratories.

SANS 18000-1:2009/

ISO/IEC 18000-1:2008

Information technology - Radio frequency identification for item management - Part 1: Reference architecture and definition of parameters to be standardized. Describes the generic architecture concepts in which item identification may commonly be required within the logistics and supply chain and defines the parameters to be determined in any standardized air interface definition in the ISO/IEC 18000 series (published in South Africa as identical adoptions under the designation SANS 18000). The subsequent parts of ISO/IEC 18000 provide the specific values for definition of the air interface parameters for a particular frequency or type of air interface, from which compliance (or non-compliance) with this part of SANS 18000 can be established. Provides a description of example conceptual architectures in which these air interfaces are often to be utilized.

SANS 19114:2004/

ISO 19114:2003

Geographic information - Quality evaluation procedures. ISO corrigendum No. Amended to exclude the lake, hospital and railway on the graphical representation of the universe of discourse, and to relabel the graphics on the map.

SANS 60079-5:2009/

IEC 60079-5:2007

Explosive atmospheres - Part 5: Equipment protection by powder filling "q". Contains specific requirements for the construction, testing and marking of electrical equipment, parts of electrical equipment and Ex components in the type of protection powder filling "q", intended for use in explosive gas atmospheres.

SANS 60332-3-25:2009/IEC 60332-3-25:2009

(Ed. 1.1)

Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category d. Consolidated edition incorporating amendment No. 1. Amended to include optical fibre cables in the standard, and to specify a precondition in the retest procedure.

SANS 60335-3-24:2009/

IEC 60332-3-24:2009

(Ed. 1.1)

Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically - mounted bunched wires or cables - Category C. Consolidated edition incorporating amendment No. 1. Amended to include optical fibre cables in the standard, and to specify a precondition in the retest procedure.

SANS 60794-2-30:2009/

IEC 60794-2-30:2008

Optical fibre cables - Part 2-30: Indoor cables - Family specification for ribbon cables. Covers optical fibre ribbon cables for indoor use.

SANS 61000-1-2:2009/

IEC TS 61000-1-2:2008

Electromagnetic compatibility (EMC) - Part 1-2: General - Methodology for the achievement of functional safety of electrical and electronic systems including equipment with regard to electromagnetic phenomena. Establishes a methodology for the achievement of functional safety only with regard to the electromagnetic phenomena of electrical and electronic systems and installations, as installed and used under operational conditions. This methodology includes the implication it has on equipment used in such systems and installations. May also be used as a guide for considering EMC requirements for other systems having a direct contribution to safety.

SANS 61000-4-3:2008/

IEC 61000-4-3:2008

Electromagnetic compatibility (EMC) - Part 4-3: testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test. IEC interpretation sheet No. 1. Added to indicate that j-3 and m-3 are to be interpreted such that amplifiers showing a deviation of more than 5,1 dB are suitable for testing.

SANS 61448-2-4:2009/

IEC 61558-2-4:2009

Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers. Applies to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry-type transformers, having a rated supply voltage not exceeding 1 100 V a.c., a rated supply frequency not exceeding 500 Hz and a rated output that does not exceed 25 kVA for single-phase transformers and 40 kVA for polyphase transformers.

SANS 61558-2-6:2009/

IEC 61558-2-6:2009

Safety of transformers, reactors, power suppl units and similar products for supply voltages up to 1 100V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers. Deals with the safety of safety isolating transformers for general applications and power supply units incorporating safety isolating transformers for general applications. Covers transformers that incorporate electronic circuits. Not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers.

SANS 61558-2-13:2009/

IEC 61558-2-13:2009

Safety of transformers, reactors, power supply  units and similar products for supply voltages up to 1 100 V - Part 2-13: Particular requirements and tests for auto transformers and power supply units incorporating auto transformers. Applies to stationary or portable, single-phase or polyphase, air-cooled (natural or forced), independent or associated dry-type transformers, having a rated supply voltage not exceeding 1 100 V a.c., a rated supply frequency not exceeding 500Hz, and a rated output that does not exceed 40 kVA for single-phase transformers and 200 kVA for polyphase transformers.